This page allows you to work out the size radiator you will need to adequately heat each room in your house.

Heat load required for a room is decided by many factors such as:

  • Insulation used, wall and ceiling
  • Windows, type, size and direction facing.
  • Walls that are external
  • Ceiling height.

 

This guide helps to work out a wattage requirement for a room. Then from the tables of radiator sizes available, we match the most suitable radiator to the room.

We also want to consider factors such as “what is the room used for”? Bedrooms usually will not require as much heat as a living room for example.

Calculation Steps:

1/    Measure room:    Length x Width x Height in Metres    = Room size in Cubic Metres Cu/m3

Example:  3.5m wide x 3.2m long x 2.4m ceiling hieght = 26.88 cu metres

2/    Multiply x wattage from Guide = Wattage required to heat this room

Example: 2 external walls =30watts per Cu/M    30 x 26.88 = 806 watts required to heat this room. My room is a bedroom so my heat requirement is likely to be lower rather than higher from a selection viewpoint. Therefore i will look for a 750watt model.

3/     Select a suitable wall space for your radiator. This can often be under a window.

Look at the room, starting near the window for suitable locations.

4/ Compare to tables for suitable model. Note there are two height ranges in the

Yali models and often there is two lengths available for a wattage size.

Example: From the tables of available LVI radiators,  I can choose from the following 750 watt models:

 

 

Model Yali

Output Dimensions in mm

Digital controls

Watts Height Length

YALI D C 03 110 11 230 08 1

750 300

1100

YALI D C 03 080 21 230 08 1

750 300

800

YALI D C 05 080 11 230 08 1 750 500

800

YALI D C 05 050 21 230 08 1

750 500

500

Options:    

  1. My window sill is 400mm high and my window is 1.2metre wide.   YALI D C 03 110 11 230 08 1
  2. My wall space where there is no furniture planned is smaller than 1m long. YALI D C 05 080 11 230 08 1
  3. Look at where power is available and ask if you want to install a new power point to suit the radiator location.

 5/    For assistance, contact Southern Cross Companies

floorplan

Thermosoft heatload calculation guide

By using the house plan as a guide you may wish to work out your own heating requirements in Watts. You can then use this wattage figure to match with a suitable Thermosoft radiator from the table, taking the physical size into consideration to fit available wall space in your room. You might need to use more than one radiator in larger rooms. It’s best to work in cubic meters, as heating is applicable to room volume rather than to floor area. On the plan you will find the wattage/cubic meter for each type of room. A room with only one external wall requires less wattage than say a room with three external walls. The figures also relate to normal insulated homes – i.e. at least R2.5 in the ceilings and R1.7 in the walls. For large windows you should add five Watts per cubic meter. For extra large windows you should add another five Watts per cubic meter. If you have double-glazing the above figures could be reduced. Please refer to Southern Cross Companies Pty Ltd. If you however prefer, Southern Cross Companies Pty. Ltd. or their representatives, will be more than happy to work out your heating requirements. We will need your house plans including the elevation and room sizes including heights.

 Explanation: W / m3 Means Watts per Cubic Meter

Please also note that the above figures relate to radiant heating only as other type of heaters,
including open ended wall mounted convention heaters, could require considerably higher wattage.

Model Yali Output Dimensions in mm
Digital controls Watts Height Length
YALI D C 03 040 11 230 03 1 250 300 400
YALI D C 03 080 11 230 05 1 500 300 800
YALI D C 03 050 21 230 05 1 500 300 500
YALI D C 03 110 11 230 08 1 750 300 1100
YALI D C 03 080 21 230 08 1 750 300 800
YALI D C 03 150 11 230 10 1 1000 300 1500
YALI D C 03 100 21 230 10 1 1000 300 1000
YALI D C 03 130 21 230 13 1 1250 300 1300
YALI D C 03 160 21 230 15 1 1500 300 1600
YALI D C 03 200 21 230 20 1 2000 300 2000
YALI D C 05 055 11 230 05 1 500 500 550
YALI D C 05 040 21 230 05 1 500 500 400
YALI D C 05 080 11 230 08 1 750 500 800
YALI D C 05 050 21 230 08 1 750 500 500
YALI D C 05 105 11 230 10 1 1000 500 1050
YALI D C 05 065 21 230 10 1 1000 500 650
YALI D C 05 130 11 230 13 1 1250 500 1300
YALI D C 05 080 21 230 13 1 1250 500 800
YALI D C 05 095 21 230 15 1 1500 500 950
YALI D C 05 125 21 230 20 1 2000 500 1250